Matrix VI EH Net

Matrix VI EH Net network controller is designed for using in the online and offline access control systems. It's designed for managemanet of the electromagnetic and electromechanical locks, turnstiles (2 x Matrix VI EH Net controllers required). The controller provides power control functionality. Matrix VI EH Net controller is easy to install and maintain.

There is a possibility to connect Matrix VI EH Net controller to the PC via USB or Ethernet/Internet network using Z-397 Guard USB/RS-485 (Z-397 Guard USB/RS-485/RS-422) or Z-397 Web converters respectively. This makes it possible to build a complete network access control system with a time tracking, event control and report building based on the software solutions.

Matrix VI EH Net controller allows you to connect external reader or exit button, electromagnetic or electromechanical lock, external buzzer, external LED, door opening sensor.

  • Purpose Lock, Power Control
    Controller type Network
    Connection types RS-485
    RS-485 lines count 1
    RS-485 connection speed 19200 Kbps, 57600 Kbps
    RS-485 maximum line length (m) 1200
    Keys count 2024
    Types of recordable keys Normal, Master, Blocking
    Events count 2048
    Key types RFID (Proximity)
    External readers protocol iButton (1-Wire), Wiegand-26, Wiegand-34, Wiegand-42, Wiegand-50
    Operating modes (basic) Normal, Blocking, Free, Wait
    Operating modes (advanced) Accept, Trigger, Power Pocket
    Access point types Door, Turnstile
    Actuator types Electromagnetic, Electromechanical, Turnstile
    Built-in reader Yes
    Built-in reader operating frequency 125 KHz
    Built-in reader standard EM Marine, HID ProxCard II
    Built-in reader reading range (cm) 2–4
  • External readers indication output 1 x 2-colored LED
    Additional power output for external readers No
    Non-volatile memory (EEPROM) Yes
    Voltage 8–24V DC
    Current consumption (mA) 45
    Bleeper Buzzer
    Visual indication 1 x 3-colored LED
    Electromagnetic lock opening duration (s) 0–25.5
    Electromechanical lock opening duration (s) 0–25.5
    MIS transistors count 1
    MIS transistors maximum current (A)
    Invalid connection protection Yes
    Operating temperature (°C) -40...+85
    Case material ABS polymer
    Dimensions (mm) 110х47х18