GUARD Net
GUARD Net network controller is designed for using in the network and standalone access control systems. The controller has changeable functionality which is determined by the loaded firmware adjusted to the task. USB port allows you to configure the controller by simple editing of text configuration file. Previously you needed separate type of controller for each solution, now it's enough to get GUARD Net and install the firmware which is suiting for specific task.
Detailed instructions as well as the minimum conductors at the terminals provides ease of installation and maintenance. Due to the three actuators (one relay and two MIS transistors) GUARD Net controller is perfect for management of the electromagnetic and electromechanical locks, turnstiles and barriers. Specific configurations provides connection to the activator lock which requiring a supply of different voltage polarity for opening and closing.
A separate fire input increases fire safety since the activation of fire alarm unlocks the passage regardless of connection with the PC.
A second RS-485 port implemented within the GUARD Net controller as a galvanically isolated RS-485 line repeater. Thus the long network circuit may builded as a multiple short galvanically isolated segments. This greatly improves the interference protection and the software will take all the devices like connected to the same RS-485 line.
-
Purpose Lock, Turnstile, Barrier Controller type Network Connection types RS-485 RS-485 lines count 2 RS-485 connection speed 19200 Kbps, 57600 Kbps RS-485 maximum line length (m) – Keys count 2 x 8168 Types of recordable keys Normal, Master Events count 8192 External readers count 1–8 External readers protocol iButton (1-Wire), Wiegand-26 Operating modes (basic) Normal, Blocking, Free, Wait Operating modes (advanced) Accept, Trigger, Evacuation, Anti-Theft, Secure, Gateway Access point types Door, Gateway, Turnstile, Activator Lock (Gate) Actuator types Electromagnetic, Electromechanical, Turnstile -
Additional power output for external readers Yes USB operating mode Host Non-volatile memory (EEPROM) Yes Voltage 9–16V DC Current consumption (mA) 100 Bleeper Buzzer Visual indication 19 x LED Relay outputs count 2 Relay outputs maximum current (A) 25А (Type C) MIS transistors count 1 MIS transistors maximum current (A) 5А Fire alarm input Yes Security alarm input Yes Operating temperature (°C) -30...+40 Case material ABS polymer Dimensions (mm) 150x150x30