CP-Z 1-GSM

CP-Z 1-GSM reader is designed for use in access control systems (ACS) using GSM 900/1800 MHz cellular communication networks and allows you to use the phone number of an incoming call or SMS message as an identifier for access control.

The received identifier as a specifix code sequence can be passed:

  • to controller via iButton (Dallas Touch Memory) or Wiegand-26/34/42/50/58 protocols
  • to personal computer via RS-485 interface using Z-397 Guard USB/RS-485 or Z-397 USB/RS-485/RS-422 converters

CP-Z 1-GSM reader features:

  • the possibility of identifying the phone number of a call or received SMS message
  • configuring of the reader settings using SMS messages
  • RS-485 interface allows you to connect the reader to the PC and gives you a possibility to receive a codes from the reader, as well as configure the parameters of the reader
  • External connector for connecting a GSM antenna allows you to increase a quality of the network connection by connecting a remote antenna
  • Purpose ACS reader
    Operating frequency 900/1800 MHz
    Key types Phone call, SMS
    Reader standard GSM
    Code transmission format BCD, HEX
    Users phone numbers 15
    Administrative phone numbers 4
    Reader protocol iButton (1-Wire), Wiegand-26, Wiegand-34, Wiegand-42, Wiegand-50, Wiegand-58
    Anti-vandal case No
    Waterproof and dustproof case No
  • iButton (1-Wire) maximum line length (m) 15
    Wiegand maximum line length (m) 100
    Voltage 8–27 DC
    Current consumption (mA) 500
    Bleeper Buzzer
    Visual indication 1 x Red LED
    Operating temperature (°C) -40...+50
    Case material ABS polymer
    Dimensions (mm) 65х65х18