CP-Z 1-GSM
CP-Z 1-GSM reader is designed for use in access control systems (ACS) using GSM 900/1800 MHz cellular communication networks and allows you to use the phone number of an incoming call or SMS message as an identifier for access control.
The received identifier as a specifix code sequence can be passed:
- to controller via iButton (Dallas Touch Memory) or Wiegand-26/34/42/50/58 protocols
- to personal computer via RS-485 interface using Z-397 Guard USB/RS-485 or Z-397 USB/RS-485/RS-422 converters
CP-Z 1-GSM reader features:
- the possibility of identifying the phone number of a call or received SMS message
- configuring of the reader settings using SMS messages
- RS-485 interface allows you to connect the reader to the PC and gives you a possibility to receive a codes from the reader, as well as configure the parameters of the reader
- External connector for connecting a GSM antenna allows you to increase a quality of the network connection by connecting a remote antenna
-
Purpose ACS reader Operating frequency 900/1800 MHz Key types Phone call, SMS Reader standard GSM Code transmission format BCD, HEX Users phone numbers 15 Administrative phone numbers 4 Reader protocol iButton (1-Wire), Wiegand-26, Wiegand-34, Wiegand-42, Wiegand-50, Wiegand-58 Anti-vandal case No Waterproof and dustproof case No -
iButton (1-Wire) maximum line length (m) 15 Wiegand maximum line length (m) 100 Voltage 8–27 DC Current consumption (mA) 500 Bleeper Buzzer Visual indication 1 x Red LED Operating temperature (°C) -40...+50 Case material ABS polymer Dimensions (mm) 65х65х18